Soft-Start 1000W 
 
 
 
The delay is intended to switch on the mains to heavy loads gradually to ensure that the switch-on current remains within certain limits and to prevent the fuses from blowing. The elements that cause high currents at switch-on are, for instance, the electrolytic capacitors in the power supply of an output amplifier. Since these are not charged at switch-on, they constitute a virtual short-circuit on the supply lines. The current can, however, be kept within limits by inserting the present delay circuit between the mains outlet and the transformer primary. The amplifier is then powered in two stages: in the first instance, the current is limited by a number of heavy-duty series resistors a second later these resistors are shunted (short-circuited) by a relay contact.
 
In the diagram, R4–R7 are the heavy-duty series resistors, each with a value of 10 ohm and rated at 5 W. They limit the switch-on current to about 5.5 A. After relay close, the 230VAC PCB rail is ready for 2000w continuous.
 
The relay is a type whose contact is rated at 2000 VA, which will be sufficient in most cases. Its supply is derived directly from the mains via potential divider R3-C1-B1-relay coil. The resistor, R3 limits the current at switch-on, after which C1 limits the current in normal operation to about 20 mA. The delay time is determined by electrolytic capacitors C2 and C3 in parallel with the relay. The delay time may be altered by suitably changing the value of one or both of these capacitors.
 
For safety’s sake, the board also has provision for a mains fuse, F1. The rating of this depends, of course, on the current drawn by the load. It should be noted that in the case of a double-mono stereo output amplifier (with separate power supplies) each of the mono amplifiers must be given a mains-on delay.
 
Note that C1 is a metallized paper type, wich is designed specially for mains voltage applications and meets stringent regulatory requirements. Finally, at all times bear in mind that the circuit is connected to the mains, so do not touch anything inside the unit during operation and make sure that all wiring is safe and secure.
 
Link for more info (DropBox) (GoogleDrive)
 
Best Regards
® 2018 (c)
moutoulos

 

Product Details
SS2KW
12 Items
Reviews

No customer reviews for the moment.

Write your review

BGY33 Linear FM BroadCast Amplifiers BroadBand 20W PCB

Soft Start (max 2KW)

Write your review
16 other products in the same category:

Follow us on Facebook